Experiencing Process MRA industrial lube plant application

PETR 154

Roberto Giardino, roberto.giardino@enitecnologie.eni.it1, Silvia Guanziroli1, Cinzia Passerini1, and Antonio Farina2. (1) EniTecnologie S.p.A, via Maritano, 26, San Donato M.se (MI), 20097, Italy, (2) Divisione Refining & Marketing - Raffineria di Livorno, Eni S.p.A, via Aurelia, 7, 57017 Stagno (LI), Italy
In a conventional base oil production plant the operating conditions needed to produce products at a desired specification are very sensitive to feed quality. At Livorno refinery an on-line Process Magnetic Resonance Analyzer (MRA) has been installed to identify the feedstock and product composition and properly set an advanced process control system. By using MRA it is possible to reduce the product quality give-away due to feed quality variation. In this work the industrial experience acquired is reported.